A standard ir test could be used to accomplish the dc test. Adventures in engineering standards behind the scenes of. Some may be different iterations based on the year of publication, please be sure you are accessing. Shared or used by two or more hv switchgear product standards use is encouraged but is not mandatory.
Its open and loosely coupled system architecture will allow components developed by others to be easily plugged into the system to augment its functionality, and equally important, allow its components to be. March 2014 ieee recommended practice for testing insulation resistance of electric machinery. Ieee std 112000 revision of ieee std 111980 ieee standard for rotating electric machinery for rail and road vehicles sponsor electric machinery committee of the ieee power engineering society approved 30 january 2000 ieeesa standards board. Randomwound stator coils and formwound coils rated below 1 kv. Whats new in the ieee 43 insulation resistance testing. Ieee guide for phasor data concentrator requirements for power system protection, control, and monitoring sponsored by the power system relaying committee ieee 3 park avenue new york, ny 100165997 usa 10 may 20 ieee power and energy society ieee std c37. The aim of an srs document is to capture requirements in an unambiguous manner in order to facilitate communication between stakeholders. Use of this web site signifies your agreement to the ieee terms and conditions a nonprofit organization, ieee is the worlds leading professional association for. Ieee 4320 ieee recommended practice for testing insulation resistance of electric machinery. Download pdf eeieee std 43 revision of ieee std 43 ieee pdf. Isee magnitude of the surface leakage current is dependent upon temperature and the amount of conductive material, i.
Ieee standard for additional mechanical specifications for. The ieee std 432000 lists the following minimum values for the polarization index for ac and dc rotating machines. Formwound coils made after 1970 should have a minimum insulation resistance of 100 megohms. Ieee std 1122004 revision of ieee std 1121996 112tm ieee standard test procedure for polyphase induction motors and generators 3 park avenue, new york, ny 100165997, usa ieee power engineering society sponsored by the electric machinery committee 4 november 2004 print. Ieee standard 432000 states that in order to avoid the effects of temperature in trend analysis, all tests should be corrected to a common base temperature of 40 degrees c using the following equation. Ieee std 41995, ieee standard techniques for high voltage testing. Ieee 432000 ieee 432000 sngpl electrical op 24 jun 03 16. Pdfacrobat reader or word version doc document file size. The ieee std 43 2000 lists the following minimum values for the polarization index for ac and dc rotating machines. In particular, it identifies the complexities of performing pi and ir tests and their limitations. Ieee std 1422007 revision of ieee std 1421991 ieee. In particular, it identifies the complexities of performing pi and ir tests and notes their limitations.
Device numbers are used to identify functions of devices shown on a schematic diagram. With this in mind, an impedance based test impedance includes resistance, inductance, capacitance and frequency compared to other test results such as resistance and inductance, could be used as the ac test. The ieee recommends revisions in the practice for testing insulation resistance of rotating machinery due to the several changes that have been made to the types of insulation used in rotating machines. Ieee standards downloads and executable files the following information is related to specific ieee standards and amendments and can be downloaded at no cost. This book is a revision of ieee std 1421991, the ieee green book. Variation in the value of insulation resistance with time.
Ieee device numbers in the design of electrical power systems, the ieee device numbers identify features of a protective device such as relay or circuit breaker. It applies to synchronous machines, induction machines, dc machines, and synchronous condensers. Ieee std p43 2000 revision of ieee std 43 2000 ieee recommended practice for testing insulation resistance of rotating machinery may 2008 draft sponsor electric machinery committee of the ieee power engineering society reaffirmed 2006 march 2000 ieee sa standards board. It must not be used or referred to as a zambian standard. It does, however, provide an acceptable alternative.
Interpss is an open development project aimed to develop an simple to use, yet powerful internet technology based software system for design, analysis, and simulation of power systems. Ieee std 43 2000 revision of ieee std 43 1974 ieee recommended practice for testing insulation resistance of rotating machinery sponsor electric. Ieee std 4332009, ieee recommended practice for insulation testing of ac electric machinery at very low frequency. This document describes the recommended procedure for measuring insulation resistance of armature and field windings in rotating machines rated 1 hp, 750 w or greater. At a, the effect of aging and dust accumulation is shown by decreasing values. Contained within this document is the general theory of insulation resistance ir and polarization index p. Testing the insulation resistance of rotating machinery. Ieee guide for the measurement of partial discharges in ac. This has been done to accommodate recognition of the base standard in a family of standards. Download ieee std 80 2000 pdf from 16 mb, ieee std 80 2000 2 pdf from 16 mb free from tradownload. When the ieeesa standards board approved a revision of ieee standard 431974 by the electric machinery committee of the ieee power engineering society, the document became ieee standard 432000, the ieee recommended practice for testing insulation resistance of rotating machinery this revision underscores the need for upgrading current practices to accommodate changes and. Ieee standard 420 was published on may 4th, 20 present version is comprised of.
Some pdf files are protected by digital rights management drm. Ieee std 1122004, ieee standard test procedure for. This recommended practice has served electrical engineers seeking electrical system grounding information since the first edition in 1956. Isbn 0738119253 ss94806 no part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. We have no amendments or corrections for this standard. The dc voltage tests procedures for the measurement of the insulation resistance and polarization index of insulated stator, and rotor windings and how to interpret the results are described in this recommended practice. Developing software requirements specification ieee std. May be applied to lv switchgear product standards standard includes a wide range of topics including. Ieee recommended practice for testing insulation resistance of electric machinery redline abstract. It reflects the experience and sound judgment of a working group made up of engineers active in the design and operation of electrical. Ieee standard for rotating electric machinery for rail and.
142 1568 481 1261 1648 1655 1382 1412 1383 476 390 1599 1378 1639 1602 1221 288 1214 747 712 320 1248 726 198 1547 239 48 290 380 1470 921 1506 781 336 981 828 1461 1288 437 1489 1290 1257 798 525 1056 478 634 1087